Emerson DeltaV Safety Instrumented System (SIS) with Electronic Marshalling Brand New In Stock

Emerson DeltaV Safety Instrumented System (SIS) with Electronic Marshalling Brand New In Stock
Optimized process reliability
Simplified safety lifecycle management
Flexibility to meet project needs
I/O anywhere you need it
Reduces installed cost of system
Field mounted capable hardware
DeltaV SIS Electronic Marshalling
Hardware Includes:
CHARM Smart Logic Solver Carrier (DIN rail mounted and
supports a redundant pair of CHARM Smart Logic Solvers,
redundant 24V DC power connectivity, and redundant
Ethernet Safety Network communication Ports).
CHARM Smart Logic Solver (provides redundant
safety logic processing and communication to up to
96 LS-CHARMs).
CHARM Base plate (DIN rail mounted with interleaving
power and bus connectors. Supports 12 LS CHARMS and
their terminal blocks, as well as connection for injected
field power).
LS CHARM Terminal Block (removable terminal block
providing terminal connections to field wiring and
physical latch for LS-CHARM).
LS CHARMs (Logic Solver Characterization Module for
each field signal. Provides basic characterization and
isolation to the redundant communication bus).
Cable Extenders that provide flexibility in
carrier mounting.
I/O bus termination (provides bus terminations for
redundant I/O bus).
Labeling features for base plate and
channel identification.
LS CHARM Types
A variety of analog and discrete LS CHARMs are available to
meet your specific requirements. The following LS CHARMs
are available:
LS AI 4-20 mA HART
LS RTD
LS Thermocouple / mV
LS AI 0-10V DC Isolated
LS DI NAMUR
LS DI 24V DC low-side sense (dry contact)
LS DI 24V DC Isolated
LS 24V DC Power
LS DO 24V DC DTA
LS DO 24V DC ETA
LS DVC HART DTA
LS DO 24V DC Redundant DTA
LS DO 24V DC Redundant ETA
LS DVC HART Redundant DTA
LS DI 120V AC Isolated
LS DI 120V AC Isolated Plus
LS DI 230V AC Isolated
I/O Terminal Block Options
There are 11 different I/O terminal blocks available to meet
the wiring needs of field signals.
Standard Terminal Block
Fused Injected Power Terminal Block
3-wire DI Fused Injected Power Terminal Block
Thermocouple / mV Terminal Block
3-wire AI Fused Injected Power Terminal Block
LS DVC Terminal Block
LS Redundant Terminal Block
LS Redundant DTA Fused Injected Power Relay
Terminal Block
LS Redundant DTA Relay Terminal Block
LS Redundant ETA Relay Terminal Block
LS Redundant DVC Terminal Block
Relay Output Terminal Block
The LS Redundant DTA Fused Injected Power Terminal
Blocks are designed for high output current applications
and requires the LS DO 24V DC Redundant DTA or ETA
CHARM to drive the relay coil. The Redundant Relay Output
Term blocks provide a normally open and normally closed
contact with the following ratings:
28.8V DC at 1 A switching current
48V DC at 0.2 A switching current
125V DC at 0.1 A switching current
250V AC at 1 A switching current
The LS Redundant DTA Relay Terminal Block can be
used with the LS DO Redundant DTA CHARM type. Refer to
specific LS CHARM specifications for wiring information.
The LS Redundant ETA Relay Terminal Block can be
used with the LS DO Redundant ETA CHARMs type. Refer to
specific LS CHARM specifications for wiring information.
The LS Redundant DVC Terminal Block can be used with
the LS DVC HART Redundant DTA CHARM Refer to specific
LS CHARM specifications for wiring information type.
The Relay Output Terminal Block is designed for high
output current applications and requires either LS DO 24V
DC DTA CHARM or LS DO 24V DC ETA CHARM. The Relay
Output Term blocks provide a normally open and normally
closed contact with the following ratings:
28.8V DC at 2.5 A switching current
48V DC at 0.2 A switching current
125V DC at 0.1 A switching current
250V AC at 2.5 A switching current
Although any signal type can be installed in any location on
the CHARM baseplates, it is recommended that AC voltage
circuits be separated from low voltage signals to comply
with safety recommendations and to mitigate induced noise
in the signals.
DeltaV SIS CSLS Capacities
Item Limit
Maximum number of CSLSs on a single SZ Controller 16
Maximum number of Remote I/O Nodes (CIOCs and/or WIOCs) reporting to a single SZ Controller 4
Maximum number of boolean secure parameters per CSLS 96
Maximum number of non-boolean secure parameters per CSLS 32
Maximum number of CSLS I/O channels on a single SZ Controller:
96 CHARMs I/O channels × 16 CSLSs
1536
Maximum number of CSLSs in a single DeltaV SIS system:
100 SZ controllers × 16 CSLSs per SZ controller
1600
Hardware Specifications
Common Environmental Specifications (all components)
Operating Temperature* -40 to 70°C (-40 to 158°F)**
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP 20
Airborne Contaminants ISA-S71.04-1985 Airborne Contaminants Class G3
Conformal coating
Shock 10 g ½-sine wave for 11 ms
Vibration 1mm Peak-to-Peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz
*Operating any electronics at the higher end of its temperature range for long periods of time will shorten its expected lifetime,
see Effects of Heat and Airflow Inside an Enclosure White Paper for more information.
**When used with all CHARM Types except the LS DI 120 V AC Isolated Plus CHARM. When used with the LS DI 120 V AC Isolated Plus CHARM,
the operating temperature range is limited to -40 to 60°C (-40 to 140°F)
We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
Contact:
Latest News
-
Omron CJ2M-CPU32 CPU with Built-in EtherNet/IP Port CJ2M-CPU32 CPU PLC Module Brand New Discounted In Stock…
March 31, 2025
-
Omron CJ1W-PA202 CJ-series Power Supply Unit CJ1W-PA202 100-240 VAC PLC Module In Stock…
March 31, 2025
-
Omron CJ1W-OD212 Digital Output Unit CJ1W-OD212 CJ-series Transistor Output Module In Stock…
March 31, 2025
-
Omron CJ1W-ID211 Digital CJ-series Input Unit CJ1W-ID211 16 x 24 VDC Inputs Screw Terminal In Stock…
March 31, 2025
-
Omron CJ1W-AD04U Universal Analog Input Unit CJ1W-AD04U CJ-series Process Analog I/O Unit In Stock…
March 31, 2025
-
Hirschmann BRS30-8TX/4SFP-EEC-HL Compact Managed Switch MAR1020-99MMMMTTTTTTTTTTTTTT999999UMMHPHHXX.X Ethernet Industrial Switch In Stock…
March 28, 2025