Product News

IFM SA5000 Flow Sensor SAD10XDBFRKG/US-100 Sensor In Stock

News January 24, 2025

IFM SA5000 Flow Sensor SAD10XDBFRKG/US-100 Sensor In Stock


IFM SA5000 Flow Sensor SAD10XDBFRKG/US-100 Sensor In Stock

Product characteristics of IFM SA5000 Flow Sensor SAD10XDBFRKG/US-100 Sensor In Stock


Flow sensor SA5000 SAD10XDBFRKG/US-100

Measurement of flow and temperature at the same time

Optimized for water, oils and air

Red/green display for clear identification of the acceptable range

With switching output, analog signal and IO-Link

The process connection can be rotated for optimum alignment

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1

Process connectionthreaded connection M18 x 1,5 Internal thread

Application

Systemgold-plated contacts

Mediawater; glycol solutions; air; oils

Note on media

low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)

high-viscosity oils with viscosity: > 40 mm²/s (40 °C)

Medium temperature[°C]-20...90

Pressure rating

100 bar10 MPa

MAWP (for applications according to CRN)[bar]100

Electrical data

Operating voltage[V]18...30 DC

Current consumption[mA]< 100

Protection classIII

Reverse polarity protectionyes

Power-on delay time[s]10

Measuring principlecalorimetric

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1

Outputs

Total number of outputs2

Output signalswitching signal; analog signal; frequency signal; IO-Link; (configurable)

Electrical designPNP/NPN

Number of digital outputs2

Output functionnormally open / closed; (configurable)

Max. voltage drop switching output DC[V]2.5

Permanent current rating of switching output DC[mA]250

Number of analog outputs1

Analog current output[mA]4...20; (scalable)

Max. load[Ω]350

Short-circuit protectionyes

Type of short-circuit protectionyes (non-latching)

Overload protectionyes

Frequency of the output[Hz]0...1000

Measuring/setting range

Probe length L[mm]45

Operating moderelative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative)

Temperature monitoring

Measuring range[°C]-20...90

Resolution[°C]0.2

Liquid media - absolute operating mode

Setting range[m/s]0.04...3

Greatest sensitivity[m/s]0.04...3

Liquid media - relative operating mode

Setting range[m/s]0.04...6

Greatest sensitivity[m/s]0.04...3

Gases - operating mode "absolute"

Setting range[m/s]0...100

Greatest sensitivity[m/s]30...100

Gases - operating mode "relative"

Setting range[m/s]0...200

Greatest sensitivity[m/s]30...100

Accuracy / deviations

Temperature drift[cm/s x 1/K]0,003 m/s x 1/K (< 20 °C; > 70 °C)

Max. temperature gradient of medium[K/min]100

Absolute operating mode

Repeatability0,05 m/s; (water; Flow velocity: 0,05...3 m/s)

Relative operating mode

Accuracy± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)

Repeatability0,05 m/s; (water; Flow velocity: 0,05...3 m/s)

Temperature monitoring

Temperature drift± 0,005 K/°C

Accuracy[K]± 0,3 / ± 1; (water; Flow velocity: 0,3...3 m/s / air; Flow velocity: > 10 m/s)

Reaction times

Response time[s]0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)

Temperature monitoring

Dynamic response T05 / T09[s]1,5 (T09); (water; Flow velocity: 0,3...3 m/s)

Software / programming

Parameter setting optionshysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color

Interfaces

Communication interfaceIO-Link

Transmission typeCOM2 (38,4 kBaud)

IO-Link revision1.1

SDCI standardIEC 61131-9

ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis

SIO modeyes

Required master port classA

Process data analog2

Process data binary2

Min. process cycle time[ms]3

Supported DeviceIDs

Type of operationDeviceID

Factory setting / ModE = (REL)533

ModE = (GAS)547

ModE = (LIQU)540

Operating conditions

Ambient temperature[°C]-40...80

Storage temperature[°C]-40...100

ProtectionIP 65; IP 67

Tests / approvals

EMC

DIN EN 60947-5-9

Shock resistance

DIN EN 60068-2-2750 g (11 ms)

Vibration resistance

DIN EN 60068-2-620 g (10...2000 Hz)

MTTF[years]132

UL approval

UL approval numberI003

File number ULE174189

Mechanical data

Weight[g]257

Housingtubular

Dimensions[mm]Ø 34 / L = 142

Materialstainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30

Materials (wetted parts)stainless steel (1.4404 / 316L); Gasket: FKM

Process connectionthreaded connection M18 x 1,5 Internal thread

Probe diameter[mm]8

Installation length EL[mm]45

Displays / operating elements

Display

Display unit6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)

Switching status2 x LED, yellow

Measured valuesalphanumeric display, red/green 4-digit

Remarks

Remarks

MW = Measured value

MEW = Final value of the measuring range

Pack quantity1 pcs.

Electrical connection

ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated



More Models:


EVC810 IIR200 PK5524 EVC005 II0011 EVC004 SI5002 IGT205 O1D100 PQ3834IFS204TA2105IFM216EVF566II5930II5697EVC002IG5596SI5010II5687KF5015VTV122SA5000E21248 PN3094SI6700E30448OY039SEY3099E11855G1501SE11252PM1608AL1930EVC146EVT006LI5131PT5404PN7299PN7209AC1254AC1258SI6800EC2082AL1102UGT524EVC086EVC003 OGH500II5689AC5222AC5218AC5233SU7000PN3093PN2160IM5115SH0500LR2050MVQ101IFC248IFC234IFC220IN5225IFT203O5E700IG6086E12339IGC222EVC714IGW201IF5888 EVC597IM5126IGT220IG5505IG5401EVS023EVC812VTV121IIS204IM0011SM9000IGT213IFT205PN2093PN2094E20005OGE101OGS100PM1506E33403


We mainly supply 
Siemens, Schneider, Honeywell, ABB, Allen Bradley, Mitsubishi, Omron, Eaton, Pepperl+Fuchs, MTL, Phoenix Contact,Weidmuller, Festo, IFM, Wago, Pilz, Degson, Sick, SMC, Norgren, Yokogawa, Yaskawa, Fluke, SEW, Emerson,Endress+Hauser,Vega, Hirschmann,Moxa, CISCO, Turck, Beckhoff, B&R, Balluff, Bifold, GE,Rittal, Proface, Wintek,Danfoss,EBM, YTC,Hach,Delta, Finder,Wohner, CHINT, Autonics,Testo, Bently Nevada, PR Electronics, Meanwell, Dell and so on .



We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.



Contact:

HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)





CONTACT ADDRESS

UNIT A1.9/F SILVERCORP INTERNATIONAL TOWER707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG

WRITE TO US

becky@hkxytech.com

CALL US

+86 027-8580 6199

MOBILE PHONE

+86 15972186287