Product News

Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived

News February 18, 2021

Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived



Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived



Features of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived

 

·  1-channel isolated barrier

·  24 V DC supply (Power Rail)

·  Input for 2-wire SMART transmitters and current sources

·  Output for 4 mA ... 20 mA or 1 V ... 5 V

·  Sink or source mode

·  Housing width 12.5 mm

·  Up to SIL 2 acc. to IEC 61508


Specification of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


Product Description of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


Input 4 mA ... 20 mA

Output 4 mA ... 20 mA


General specifications of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived

Signal type Analog input


Functional safety related parameters of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived

Safety Integrity Level (SIL) SIL 2


Supply of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


Connection Power Rail or terminals 9+, 10-

Rated voltage 19 ... 30 V DC

Ripple ≤ 10 %

Rated current ≤ 45 mA

Power dissipation ≤ 800 mW

Power consumption ≤ 1.1 W



Input of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


Connection side field side

Connection terminals 1+, 2-; 3+, 4-

Input signal 4 ... 20 mA limited to approx. 30 mA

Open circuit voltage/short-circuit current terminals 1+, 2-: 22 V / 30 mA

Voltage drop terminals 3+, 4- : approx. 5 V

Available voltage terminals 1+, 2-: ≥ 15 V at 20 mA


Output of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


Connection side control side

Connection terminals 5-, 6+

Load 0 ... 300 Ω (source mode)

Output signal 4 ... 20 mA or 1 ... 5 V (on 250 Ω, 0.1 % internal shunt) 

4 ... 20 mA (sink mode), operating voltage 15.5 ... 26 V

Ripple 20 mV rms


Transfer characteristics of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


Deviation at 20 °C (68 °F) 

≤ ± 0.1 % incl. non-linearity and hysteresis (source mode 4 ... 20 mA) 

≤ ± 0.2 % incl. non-linearity and hysteresis (sink mode 4 ... 20 mA) 

≤ ± 0.2 % incl. non-linearity and hysteresis (source mode 1 ... 5 V)

Frequency range field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) 

control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)

Settling time ≤ 200 ms

Rise time/fall time ≤ 20 ms


Ordering Models of Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB  KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26

 

Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived

 

KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-STC5-Ex1.2O.H KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-STC5-Ex1.2O.H  KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26 KFU8-FSSP-1.D NBB0,8-5GM25-E2 NBB1,5-8GM50-E0 NBB10-30GM40-Z0 NBB10-30GM50-E2 NBB15-30GM50-WO NBB15-30GM50-WS NBB15-U1-A2 NBB15-U1-A2-T NBB15-U1-E2 NBB15-U1-Z2 NBB2-12GM50-E0-V1 NBB2-12GM50-E2 NBB2-6,5M30-E0 NBB2-8GM30-E2-5M NBB20-L2-A2-V1-3G-3D NBB20-L2-E0-V1 NBB20-L2-E2-V1 NBB20-U1-A2 NBB20-U1-E0 NBB20-U1-E2 NBB3-V3-Z4 NBB4-12GM50-E0 NBB4-12GM50-E0-V1 NBB4-12GM50-E2-V1 NBB5-18GM50-E2-V1 NBB5-18GM60-A2-V1 NBB8-18GM50-E2-V1 NBB8-18GM60-A2-V1 NBN12-18GM50-E2-V1 NBN12-18GM50-E2-V1-Y261468 NBN15-30GM50-E0 NBN15-30GM50-E2-V1 NBN15-30GM60-A2 NBN25-30GM50-E2 NBN3-F31-E8-V1 NBN30-L2-E2-V1 NBN30-U1-A2 NBN30-U1-E2 NBN4-12GM50-E2 NBN4-12GM50-E2-V1 NBN40-L2-E2-V1 NBN40-U1-A2 NBN40-U1-A2-T NBN40-U1-Z2 NBN40-U1K-N0 NBN5-F7-E0 NBN5-F7-E2 NBN8-12GM50-E0-V1 NBN8-12GM50-E2-V1 NBN8-18GM50-E0 NBN8-18GM50-E2-V1 NBN8-18GM60-WS NCB10-30GM40-NO NCB15-30GM50-Z5 NCB50-FP-A2-P1 NCB8-18GM40-N0 NCN15-30GM40-Z1 NJ15+U1+DW1-10 NJ2-12GK-SN NJ2-V3-N NJ4-12GK-N NJ40-FP-SN-P1 NJ5-18GM-N NJ5-18GM50-A2-V1 NJ8-18GM-N NRB10-30GM50-E2-C-V1 NRB15-30GM50-E2-C-V1

 

Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived

 

KCD2-SR-Ex1.LB KCD2-SR-Ex2 KFA6-DU-Ex1.D KFA6-ER-Ex1.W.LB KFA6-SOT2-Ex2 KFA6-SR2-Ex1.W KFA6-SR2-Ex1.W.LB KFA6-SR2-Ex2.W KFA6-SR2-Ex2.W.IR KFD2-DU-Ex1.D KFD2-ELD-Ex16 KFD2-ER-Ex1.W.LB KFD2-SH-Ex1 KFD2-SH-Ex1.T.OP KFD2-SOT3-Ex1.LB KFD2-SOT3-Ex1.LB.IO KFD2-SOT3-Ex2 KFD2-SOT3-Ex2.IO KFD2-SR2-Ex1.W KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-SR3-Ex2.2S KFD2-SRA-Ex4 KFD2-ST3-Ex1.LB KFD2-ST3-Ex2 KHA6-SH-Ex1 KCD2-SON-Ex1 KCD2-SOT-Ex1.LB KCD2-SOT-Ex2 KCD2-SOT-Ex2.SP

 

Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived

 

KCD2-SR-Ex1.LB.SP KCD2-SR-Ex2.SP KCD2-ST-Ex1.LB KCD2-ST-Ex2 KFA5-SOT2-Ex2 KFA5-SR2-Ex1.W KFA5-SR2-Ex1.W.LB KFA5-SR2-Ex2.W KFA5-SR2-Ex2.W.IR KFD2-SH-Ex1.T KFD2-SOT3-Ex2.IO-Y1 KCD2-SON-Ex1.R1  KCD2-SON-Ex1.SP KCD2-SON-Ex2 KCD2-SON-Ex2.R1 KCD2-SON-Ex2.SP KCD2-SOT-Ex1.LB.SP KCD2-ST-Ex1.LB.SP KCD2-ST-Ex2.SP KFA4-SR2-Ex2.W KFA5-DU-Ex1.D KFA4-SR2-Ex1.W KFA4-SR2-Ex1.W.LB KFD2-SOT2-Ex1.LB KFD2-SOT2-Ex1.LB.IO KFD2-SOT2-Ex2 KFD2-SOT2-Ex2.IO KFD2-SOT2-Ex2.IO-Y181008 KFD2-SR2-Ex2.2S KFD2-ST2-Ex1.LB KFD2-ST2-Ex2

 

Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KFD2-STC4-EX1 KFD2-SR2-EX1.W KFD2-SR2-EX2.W KFD2-CD-EX1.32 KFD2-UT2-EX1. KFD2-ST-EX1 KFD2-UFC-EX1.D KFA5-SR2-EX2.W KFA5-SR2-EX1.W KFA6-SR2-EX2.W KFA5-SR2-EX1.W KFD2-ST-EX1 KFD2-SOT2-EX1 KFU8-UFC-EX1.D KFD2-CD-EX1.32 KFU8-FSSP-1.D KFA6-DWB-EX1.D KFD2-DWB-EX1.D KFA5-SR2-EX1,W KFA5-SR2-EX2,W KFD2-VR4-EX1.26 KFD2-STC4-EX1.20 KFD2-SOT2-EX2 KFD2-ST2-EX1.B KFD2-DWB-EX1.D KFD2-UFC-EX1.D KFA6-STR-1.24.500 KFD2-UT2-1 KFD2-UT2-2 KFD2-CD-1.32 KFD2-SOT2-EX1.LB KFA6-SR2-EX1.LB KFA6-SOT2-EX2 KFU8-FSSP-1.D KFU8-UFC-EX1,D KFU8-UFT-EX2.D KFA6-DWB-EX1.D KFD0-SCS-EX1.55 KFD2-STC4-EX2 KFD2-STC4-EX1Y125882 KFD2-UT2-EX2 UPR-03 KFD2-EB2.B4.AB KFD2-CD-EX1.32 KFD2-STC4-EX1 KFD2-UT2-EX1 KFD2-SR2-Ex1.W KFD2-SCD-EX1.LK KFD2-SOT2-EX2 KFD2-STC4-EX2 KFD2-SR2-Ex2.W KFD2-SR2-Ex1.W KFD2-STC4-EX1.2O KFD0-SCS-EX1.55 KFU8-UFC-EX1.D KFD2-SOT2-EX2 KFD2-STC4-EX1 KFD2-UT2-EX2 KFD2-VR4-EX1.26 KFD2-EB2.R4A.B KFD2-BR-1.PA.93 KFU8-DWB-1.D KFU8-DW-1.D KFU8-UFT-EX2.D Z787.H UPR-03


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


BTC12N-*

Industrial Box Thin Client

Industrial box thin client for demanding 24/7 use. Simple virtualization of host systems through the pre-installed Pepperl+Fuchs VisuNet Shell 5 firmware. The BTC12 from the virtualization portfolio of Pepperl+Fuchs realizes a reliable and future-oriented visualization due to the 2x DisplayPort (4K @ 60Hz), the dual LAN and the long-term availability of the individual components. Power Supply needs to be ordered separately.


FB9206D3

Power supply

Power supply for 24 V DC, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


FSP065-RBBN3

Power supply

Power supply for BTC12 and BTC14 Industrial thin clients, DC jack with lock mechanism, Package includes EU-type F and US-type B power cords and hook-and-loop fastener


HCD2-FBPS-1.23.500

Fieldbus Power Hub, Compact Power Supply Module

Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA


HCD2-FBPS-1.500

Fieldbus Power Hub, Compact Power Supply Module

Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA


HD2-DM-A

Fieldbus Power Hub, Advanced Diagnostic Module

Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA


HD2-DM-B

Fieldbus Power Hub, Basic Diagnostic Module

Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA


K24-STR-24..30VDC-10A

Power supply

Power supply, 24 to 30 V DC, 10 A


KFA6-STR-1.24.500

Power Supply

115/230 V AC supply, Output 24 V DC, 500 mA, Electronic short circuit protection, Power Rail connection


KFD0-SCS-Ex1.55

SMART Current Driver/Repeater

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system


KFD2-CRG2-1.D

Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511


KFD2-CRG2-Ex1.D

Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511


KFD2-HLC-Ex1.D

HART Loop Converter

1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad


KFD2-HLC-Ex1.D.2W

HART Loop Converter

1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 2 relay contact outputs (change-over contacts), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad


KFD2-STC5-1

SMART Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STC5-1.2O

SMART Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508


KFD2-STC5-2

SMART Transmitter Power Supply

2-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STC5-Ex1.2O

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508


KFD2-STC5-Ex1.H

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 2 acc. to IEC 61508


KFD2-STC5-Ex2

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KFU8-CRG2-1.D

Transmitter Power Supply

1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511


KFU8-CRG2-Ex1.D

Transmitter Power Supply

1-channel isolated barrier, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire 

current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable 

high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511


KFU8-VCR-1

Transmitter Power Supply/Converter

1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC


KLD2-FBPS-1.25.360

Fieldbus Power Supply

Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1


LB3102A2

HART Transmitter Power Supply, Input Isolator

1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA


LB3105A2

HART Transmitter Power Supply, Input Isolator

4-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2-wire transmitters with 4 mA ... 20 mA


LB9006C

Power supply

Power supply for 24 V, Permits vertical or horizontal mounting in Zone 2, Use three power supplies for redundancy, Galvanic zisolation to mains


VAN-115/230AC-K27

AS-Interface power supply

AS-Interface power supply, data decoupling, 4 A


FB3205B3

HART Transmitter Power Supply, Input Isolator

4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)

LB9029BP12320.1

Redundancy Base Backplane

Backplane for LB-System, For PROFIBUS DP, PROFIBUS DP V1, PROFINET, and MODBUS RTU, Max. 12 slots for I/O modules, Redundancy (field bus and power supply)


KFD2-STC5-Ex1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508


FB3202B2

HART Transmitter Power Supply, Input Isolator

1-channel, Input Ex ia, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA, Module can be exchanged under voltage (hot swap)


FB3205B2

HART Transmitter Power Supply, Input Isolator

4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


FB9206D

Power supply

Power supply for 24 V DC, Suitable for the supply of 24 I/O modules and 1 bus coupler, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


FB9215B2

Power supply

Multi range power supply 90 ... 253 V AC, Suitable for the supply of 24 I/O modules and 1 bus coupler, Use two power supplies for redundancy, Installation in suitable enclosures in Zone 1


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


HiC2025

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Low power dissipation, Up to SIL 2 acc. to IEC 61508


HiC2025ES

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508


HiC2027

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Up to SIL 2 acc. to IEC 61508


HiD2024

SMART Transmitter Power Supply/Current Driver

4-channel isolated barrier, 24 V DC supply (bus powered), Analog in or analog out signals, Sink and source mode outputs, SMART pass-through, Up to SIL 2 acc. to IEC 61508


IO-Link-Master02-USB

IO-Link Master

IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connection


K26-STR-24VDC-2A

Power supply

Power supply, 24 V DC, 2 A


KCD2-STC-1.2O

SMART Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508


KCD2-STC-Ex1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508


KCD2-STC-Ex1.2O

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508


KCD2-STC-Ex1.ES

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508


KCD2-STC-Ex1.SP

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KFA6-STR-1.24.4

Power Supply

115/230 V AC supply, Output 24 V DC, 4 A, Fused output, Power Rail connection


KFD0-CS-1.50

Repeater

1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system


KFD0-CS-2.50

Repeater

2-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system


KFD0-CS-Ex1.50P

Repeater

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system


KFD0-CS-Ex1.51P

Current Driver/Repeater

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system


KFD0-CS-Ex2.50P

Repeater

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system


KFD0-CS-Ex2.51P

Current Driver/Repeater

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system


KFD2-STC3-Ex1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 4 mA ... 20 mA, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points


KFD2-STC4-Ex2-Y1

SMART Transmitter Power Supply, Output Current Sink

2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508


KFD2-STC5-Ex1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STC5-Ex1.2O.H

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 3 acc. to IEC 61508


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


LB3002A2

HART Transmitter Power Supply, Input Isolator

1-channel, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA, Installation in Zone 2 or safe area, Supply circuit 15 V (20 mA)


LB3005A2

HART Transmitter Power Supply, Input Isolator

4-channel, Power supply for 2-wire transmitters with 4 mA ... 20 mA, Installation in Zone 2 or safe area, Supply circuit 15 V (20 mA)


LB3106A

HART Transmitter Power Supply

4-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2-wire transmitters with 4 mA ... 20 mA


LB9022BP22320.0.E

Redundancy Base Backplane

Backplane for LB-System, For MODBUS TCP/IP, Max. 22 slots for I/O modules, Redundancy (field bus and power supply)


M-UPR-03-S

Universal Power Rail

3-conductor insert for base module, Provides the power supply of the plugged modules, Transfers a fault signal or a maintenance signal, Standard length 0.8 m (2.6 ft), simple to customize to application space


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


ODZ-MAH-SUPPLY

Power supply

Power supply


PCV-KBL-V19-STR-USB

Cable unit

USB cable unit with power supply, Power supply for 95 - 230 V AC, For SSI interface, For PROFIBUS DP, For CANopen, For 


PROFINET, For EtherNet/IP


PCV-USB-RS485-Converter Set

Interface converter

USB to RS 485 interface converter, Extension cable 0.8 m in scope of delivery, Power supply for 95 - 230 V AC, For RS485


PR-03

Power Rail

Alternative power supply, Nominal current 4 A, Simple installation, Standard length 50 cm, can be shortened to any length in 


4 cm steps, Terminating insulation by end cap, included in the delivery package, With 2 leads for voltage supply and 1 lead for centralized error messages


PS1000-A6-12.16

Power Supply

100 V AC to 240 V AC wide-range input, Housing width 39 mm, Efficiency up to 94.3 %, Minimal inrush current surge, Remote control for ON/OFF, DC OK relay contact


PS1000-A6-24.10

Power Supply

100 V AC to 240 V AC wide-range input, Housing width 39 mm, Efficiency up to 95.2 %, Minimal inrush current surge, DC OK relay contact


PS1000-A6-24.10.R

Power Supply

100 V AC to 240 V AC wide-range input, Housing width 39 mm, Built-in decoupling mosfet for 1+1 and N+1 redundancy, Efficiency up to 94.7 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel operation


PS1000-A6-24.20

Power Supply

100 V AC to 240 V AC wide-range input, Housing width 48 mm, Efficiency up to 95.6 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel operation


PS1000-A6-24.20.R

Power Supply

100 V AC to 240 V AC wide-range input, Housing width 48 mm, Built-in decoupling mosfet for 1+1 and N+1 redundancy, Efficiency up to 95.2 %, Minimal inrush current surge, DC OK relay contact, Current sharing for parallel operation


PS1000-A6-24.5

Power Supply

100 V AC to 240 V AC wide-range input, Housing width 32 mm, Efficiency up to 94.3 %, Minimal inrush current surge, DC OK relay contact


PS1000-A6-48.5

Power Supply

100 V AC to 240 V AC wide-range input, Housing width 39 mm, Efficiency up to 95.5 %, Minimal inrush current surge, DC OK relay contact


PS3500-PM-1.24.15

PS3500 Power Supply Module

PS3500 Power Supply Module - 22.5 V - 30 V


PSU-IDMx61-BC-N0-N0

Power supply

Power supply for IDM* non-Ex base station and charger, AC and DC power supplies for IDM* non-Ex base station and charger, Adapters for EU-type F and US-type B power cords


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


S1SD-1AI-1C.H

SMART Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire SMART transmitters and current sources, Output 0/4 mA ... 20 mA, Accuracy 0.1 %, Connection via screw terminals


S1SD-1AI-1U

Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire transmitters and 2-wire current sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals


S1SD-1AI-2C

Transmitter Power Supply/Signal Splitter

1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Dual output 0/4 mA ... 20 mA, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals


VAN-115/230AC-K16

AS-Interface power supply

AS-Interface power supply, data decoupling, 8 A


VAN-115/230AC-K19

AS-Interface power supply

AS-Interface power supply, data decoupling, 2,8 A


VAN-230/500AC-K24

AS-Interface power supply

AS-Interface power supply, data decoupling, 8 A


VAN-G4-PE-4A

AS-Interface power supply

AS-Interface power extender


FB3202B1

HART Transmitter Power Supply, Input Isolator

1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


FB3204B2

Transmitter Power Supply, Input Isolator

4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


FB3302B2

HART Transmitter Power Supply, Input Isolator

1-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


FB3305B2

HART Transmitter Power Supply, Input Isolator

4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


FB9205C

Power supply

Power supply for 95 - 230 V AC, Suitable for the supply of FOL, field products (analyzers, level meters etc.), Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


HD2-DM-A.RO

Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output

Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA


HiC2025A

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Low power dissipation, Reduced intrinsically safe parameters, Up to SIL 2 acc. to IEC 61508


HiC2025HC

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Low power dissipation, Suitable for long field cables (> 1000 m), Up to SIL 2 acc. to IEC 61508


HiC2027DE

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Up to SIL 2 acc. to IEC 61508


HiC2027ES

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Up to SIL 3 acc. to IEC 61508


HiSHPMM/64/CONA-01

HART Termination Board

64-channel, 24 V DC supply, Connection of two Multiplexers to HART enabled Honeywell TDC 3000 FTA's , Redundant power supply connections, Dual RS 485 connections, HART loop connection via four 20-pin flat ribbon connectors, Compact design


HiSHPTB/32/HONB-AI-01

HART Termination Board

TDC 3000 replacement FTA, Short-circuit protected, Process control system wirings, Redundant power supply connections, Field terminal blocks that are Honeywell FTA compatible, Honeywell "B" size footprint


HiSHPTB/32/HONB-AI-R-01

HART Termination Board

TDC 3000 replacement FTA, Short-circuit protected, Redundant PCS wirings, Redundant power supply connections, Field terminal blocks that are Honeywell FTA compatible, Honeywell "B" size footprint


HiSHPTB/32/HONB-AO-R-01

HART Termination Board

TDC 3000 replacement FTA, Short-circuit protected, HART analog output filters, Redundant PCS wirings, Redundant power supply connections, Field terminal blocks that are Honeywell FTA compatible, Honeywell "B" size footprint


K34-STR-24..30V-3X500VAC-10A

Power supply

Switched mode power supply, 23 ... 30 V DC, 8 A


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KCD2-STC-Ex1.2O.DE

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508


KCD2-STC-Ex1.2O.ES

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508


KCD2-STC-Ex1.ES.SP

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KCM-51-C

Counter

Electromechanical summator, 5 decade devices, Counter frequency 10 Hz, Manual reset, Power supply 24 V DC


KCM-51-V

Counter

Electromechanical summator, 5 decade devices, Counter frequency 10 Hz, Manual reset, Power supply 230 V AC


KCM-70-C

Counter

Electromechanical summator, 7 decade devices, Counter frequency 10 Hz, Without reset, Power supply 24 V DC or 230 V AC


KCM-70-V

Counter

Electromechanical summator, 7 decade devices, Counter frequency up to 25 Hz, Without reset, Power supply 24 V DC or 230 V AC


KCM-70A-C

Counter

Electromechanical summator, 7 decade devices, Counter frequency up to 25 Hz, Without reset, Power supply 24 V DC or 230 V AC


KCM-70A-V

Counter

Electromechanical summator, 7 decade devices, Counter frequency up to 25 Hz, Without reset, Power supply 24 V DC or 230 V AC


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


KFD0-CS-2.51P

Current Driver/Repeater

2-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system


KFD0-SCS-1.55

SMART Current Driver/Repeater

1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field to the control system


KFD2-HLC-Ex1.D.4S

HART Loop Converter

1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 4 relay contact outputs (NO contact), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad


KFD2-STC4-Ex1.2O-Y1

SMART Transmitter Power Supply, Output Current Sink

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508


KFD2-STV4-Ex1-2

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STV4-Ex1.2O-1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508


KFD2-STV4-Ex2-1

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STV4-Ex2-2

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STV5-Ex1-1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KLD2-FBPS-1.12.220

Fieldbus Power Supply

Output: 12 ... 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


LB3006A

HART Transmitter Power Supply

4-channel, Power supply for 2-wire transmitters with 4 mA ... 20 mA, Installation in Zone 2 or safe area, Supply circuit 21.5 V (4 mA)


LB3104A2

Transmitter Power Supply, Input Isolator

4-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2-wire transmitters with 4 mA ... 20 mA


MINI-PS-100-240AC/24DC/1.3

Power supply

Reliable power supply unit even at high ambient temperatures, Can be used worldwide in all industrial sectors due to a wide-range input and an international approval package


ODZ-MAC-PWR-24V

24 V DC power supply

24 V DC power supply


PCV-KBL-V19-STR-RS485

Cable unit

Cable unit with power supply for USB / RS-485 interface converter , Power supply for 95 - 230 V AC


PR-05

Power Rail

Alternative power supply, Nominal current 4 A, Simple installation, Standard length 50 cm, can be shortened to any length in 4 cm steps, Terminating insulation by end cap, included in the delivery package, With 2 leads for power supply, 2 leads for bus connections and 1 lead for centralised error messages or HART signal transfer (with RPI-system)


PS1/31

Power supply

Switching device for the simple electrical connection of sensors, Relay output for high power, 10-way programming switch for time functions and switching connection modes, Function: Switch device for sensor supply


PS3500-TB-3

PS3500 Power Supply Backplane - 3-position

3 position backplane for use with PS3500 Power Supplies.


PS3500-TB-6

PS3500 Power Supply Backplane - 6-position

6 position backplane for use with PS3500 Power Supplies.


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


PSU1100-J1-AC-N0

AC Power Supply

AC Power Supply, Certified for ATEX and IECEx Zone 1/21, UL listed for USA and Canada, Galvanic isolation between input and output, Provides an output power up to 80 W at 24 V DC, Fully IP66 rated


PSU1100-J1-DC-N0

DC Power Supply

DC Power Supply, Certified for ATEX and IECEx Zone 1/21, UL listed for USA and Canada, Galvanic isolation between input and 


output, Provides an output power up to 80 W at 24 V DC, Fully IP66 rated


PSU1200-J2-AC-N0

AC Power Supply

AC Power Supply, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canada, Galvanic isolation between input and 


output, Provides an output power up to 80 W at 24 V DC, Fully IP66 rated


PSU1200-J2-DC-N0

DC Power Supply

DC Power Supply, Certified for ATEX and IECEx Zone 2/22, UL listed for USA and Canada, Galvanic isolation between input and output, Provides an output power up to 80 W at 24 V DC, Fully IP66 rated


Power Supply Set for Cube 800

Power Supply & USB-Cable for Cube 800

Power Supply & USB-Cable for Cube 800


USB-FBPS-1.11.45.NI

USB Fieldbus Power Supply

USB Fieldbus Power Supply, Output: min. 11 V/45 mA, For 1...2 devices/test setups, In conjunction with NI PCMCIA-FBUS card, Permitted for Zone 2 operation, For FOUNDATION Fieldbus H1


VBG-CCL-K30-D-S32-EV

AS-Interface Gateway/Safety Monitor

CC-Link gateway with integrated safety monitor, power supply input with decoupling coils



VBG-ENX-K30-DMD-S16-EV

AS-Interface Gateway/Safety Monitor

EtherNet/IP + Modbus TCP Gateway with integrated safety monitor, double master for 2 AS-Interface networks, power supply input with data decoupling


VAN-24DC-K28

AS-Interface power supply

AS-Interface power supply, data decoupling, 4 A, 24 V DC input voltage


VBG-PN-K30-DMD-S32-EV

AS-Interface Gateway/Safety Monitor

PROFINET Gateway with integrated safety monitor, double master for 2 AS-Interface networks, power supply input with decoupling coils


AVS58N-011YYRYGN-0014

Singleturn absolute encoder

YY: Connector 9416L with special assignment, Y: Power supply 5 V DC, 14 Bit singleturn, Hardware encoder, Data transfer up to 2 MBaud

FB9262BP10220.1

Universal Backplane

Universal backplane, Max. 10 slots for I/O modules, Redundancy (field bus and power supply), Installation in Zone 1

FB9262BP20220.1

Universal Backplane

Universal backplane, Max. 20 slots for I/O modules, Redundancy (field bus and power supply), Installation in Zone 1


HiSHPTB/32/FOX2001C-02

HART Termination Board

IA 200 replacement FTA, Designed for FBMs 201, 204, 215 and 237, 25-pin Sub-D connectors, PCS wiring, Redundant power supply connections, Easy to add line impedance

FB9271BP00200.0

Backplane

Backplane for FB9205 Power Supply, Slots for 2 power supplies, Powert supplies ca be operated separately or parallel, Redundant supply


ODZ-MAH-5V-110V

Power supply

Power supply


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


HiD2022

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (bus powered), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current source, Up to SIL 2 acc. to IEC 61508


HiD2022SK

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (bus powered), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink, Up to SIL 2 acc. to IEC 61508


HiD2030

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA ... 20 mA or 1 V ... 5 V, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508


HiD2030SK

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA ... 20 mA, current sink, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508


KCD2-STC-1

SMART Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508


KFD2-STC4-Ex1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STC4-Ex1-Y1

SMART Transmitter Power Supply, Output Current Sink

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508


KFD2-STC4-Ex1.2O

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508


KFD2-STC4-Ex1.H

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, High field voltage 17.6 V DC, Up to SIL 2 acc. to IEC 61508


KFD2-STC4-Ex2

SMART Transmitter Power Supply

2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


VAN-KE2-2PE

AS-Interface power supply

AS-Interface power extender


HD2-FBPS-1.17.500

Fieldbus Power Hub, Power Supply Module

Output: 15 ... 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA


HD2-FBPS-1.23.500

Fieldbus Power Hub, Power Supply Module

Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA


HD2-FBPS-1.25.360

Fieldbus Power Hub, Power Supply Module

Output: 25 ... 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA


HD2-FBPS-1.500

Fieldbus Power Hub, Power Supply Module

Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA


KCD2-STC-1.SP

SMART Transmitter Power Supply

1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508


KFD2-STC4-Ex1.2O.H

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, High field voltage 17.6 V DC, Up to SIL 3 acc. to IEC 61508


KFD2-STV4-Ex1-1

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508


KFD2-STV4-Ex1.2O-2

SMART Transmitter Power Supply

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/2 V ... 10 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508


KLD2-PR-Ex1.IEC

Fieldbus Power Repeater

Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment


KLD2-PR-Ex1.IEC1

Fieldbus Power Repeater

Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


ODZ-MAC-CAB-24V-R2-2M

Connecting cable for power supply/RS 232

Connecting cable for power supply/RS 232


WHA-GW-F2D2-0-AS-Z2-ETH

WirelessHART Gateway

MODBUS WirelessHART Gateway, Graphical network analysis, Simple and automatic configuration options, Ethernet and RS 485 interface, HART and MODBUS protocol via both interfaces, Input WirelessHART wireless interface, 24 V DC supply, Redundant power supply connections


WHA-GW-F2D2-0-AS-Z2-ETH.EIP

WirelessHART Gateway

EtherNet/IP WirelessHART Gateway, Graphical network analysis, Simple and automatic configuration options, Ethernet and RS 485 interface, HART protocol via both interfaces, EtherNet/IP protocol via Ethernet interface, Input WirelessHART wireless interface, 24 V DC supply, Redundant power supply connections


TC-6A-V

Counter/Timer/Tachometer

Counter/Timer/Tachometer with analog voltage and current output, Bright 6-digit LED indicator, AC/DC multi-range power pack, Counter frequency up to 25 kHz, Power supply for pulse generator


VBG-EC-K30-DMD-S32-EV

AS-Interface Gateway/Safety Monitor

EtherCat gateway with integrated safety monitor, double master for 2 AS-Interface networks, power supply input with decoupling coils


LB3103A2

HART Transmitter Power Supply, Input Isolator

1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA


AS-Interface Power Calculator

AS-Interface software

Software

AS-Interface Power supply and network checking utility


ENT-DC-30

Ex i power supply

Power Supply Module and Interface adapter, For installation in the safe area, Particularly suitable for TERMEX operator workstations and Power-Scan barcode readers


FB3203B2

HART Transmitter Power Supply, Input Isolator

1-channel, Fully compatible replacement for FB3203B, Input Ex ia, Installation in suitable enclosures in Zone 1


LB3101A2

Transmitter Power Supply, Input Isolator

1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA


MBHC-FB-4.GT*

Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules

4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics


PSU-IDMx60-*

Power Supply

Power supply for IDM* handheld readers and base stations , AC and DC power supplies for IDM-Z1-* handheld readers and base station, Enable operation in Zone 1/21, Sturdy aluminum housing


SK-IDM-Z1-x60-*

Supply Module

Power supply for IDM-Z1-* handheld readers and base station, AC and DC power supplies for IDM-Z1-* handheld readers and base station, Enable operation in Zone 1/21, Sturdy aluminum housing


Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply KCD2-STC-Ex1 Safety Barriers Arrived


We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.

 

 

We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL, Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada etc.

 

Contact:

HONGKONG XIEYUAN TECH CO., LIMITED

Email:becky@hkxytech.com   Web:www.hkxytech.com

Mobile:+86-15972186287(Whatsapp & Wechat)


CONTACT ADDRESS

UNIT A1.9/F SILVERCORP INTERNATIONAL TOWER707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG

WRITE TO US

becky@hkxytech.com

CALL US

+86 027-8580 6199

MOBILE PHONE

+86 15972186287